Multimeter/Network Analyzer

RPM80 digital multifunction power analyser-class S

RPM80 digital multifunction power analyser-class S
Description
● True RMS measurements (512 samples/cycle)
● For single-phase, two-phase, three-phase system
● Measurements:VL-L, VL-N, I, In, Cos∅, Pf, Hz, W, ∑W, Va, ∑Va, 
      Var, ∑Var, import Kwh, export Kwh  import Kvarh, export Kvarh, V-THD, 
      I-THD, 1-63th harmonic , system running hours, % voltage unbalance, 
      % current unbalance, % system load, total frequency,
● 3 voltage and 4 current input
● Measure or calculate the neutral current
● Voltage Input: 0-690Vac, Current input: 1 or 5A CT selective
● % system load and system running hours
● Maximum, minimum and demand for U, I, P, Q, S in hours, days, months
● Real time clock with integrated backup rechargeable battery
● Four quadrants energy measurement and Monthly energy calculation
● 7 digital input and 2 relay output(remote or alarm) or analog output
● 2 pulse output  and  RS485 or Ethernet communication(Modbus RTU /TCP)
● Waveforms capture and phase diagram for voltage, current
● Alarm event log
● Data recorded in standard excel file formats for further En50160 analysis
● English, Chinese (traditional & simplied) 


Optional
● Four quadrants energy measurement and electric CO2 emissions accumulate
● Monthly energy and electric CO2 emissions calculation and recording
● Leakage current indication
● Other language

 
Characteristics
RPM80
Auxiliary supply
Operating voltage (Un)
85···265 VAC 50/24-48VDC,4VA(Depend on order)
Power consumption
4VA
Frequency
45···65Hz
Voltage measurement input
Measurement range
10···690VAC L-L
Measuring mode
True RMS
Measuring input impedance
4MΩ
Method of connection
single-phase,two-phase,three-phase
Current measurement input
Reference current
1A or 5A
Measuring range
0,05···5.5A
Measuring mode
True RMS
Overload capacity
10A (Through the external current transformer)
Self-consumption
0,2VA
Accuracy
 
 
Measures
Voltage
± 0,2% according to IEC61557-12
Current
± 0,2% according to IEC61557-12
Power
± 0,5%
Power factor
± 0,5%
Harmonics
± 1%
Frequency
± 0,02%
Active Energy ±
CL 0.5S according to IEC62053-22
Reactive Energy ±
CL 0.5S according to IEC62053-22
Insulation
Insulation voltage
3kV for 1min,50Hz
Display
Display type                                                   240x160 pix LCD
Ambient condition
Opterating temperature
-10···+55°C
Storage temperature
-25···+75°C
Housing
 
 
Flush mount 96*96mm
 
Size                                                
The panel cut-size 92*92mm
 
Degree of protection
 
IP40(optional IP54) on front
 
IP20 housing and terminals
Weight
400g
Standard
  
Reference standard
EN61010.1; EN60529; EN62053-21; EN62053-23;
N61000-4-2; EN61000-4-3; EN61000-4-4; EN61000-4-5; EN61000-4-6;EN61000-4-8; EN61000-4-11;EN61000-3-2
►Measuring: VL-L, VL-N, I, In, Cos, Pf, Hz, W, ΣW, Va, ΣVa,Var, ΣVar, Kwh, Kvarh, THD-U, THD-I, 1-63th harmonics
►Real time clock
►System running hours
►1-24 months energy calculate and recording
7 digital input and 2 relay output(remote or alarm) or analog output
►Waveforms and phase diagram for voltage, current
Waveform record and sag, swell and transient event capture.
►Alarm event Log(over and under): VL-L, VL-N, I, In, ΣW, ΣVar,THD-U, THD-I
RS485 communication (MODBUS RTU)